TECHNET Archives

September 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Hfjord <[log in to unmask]>
Date:
Thu, 20 Sep 2007 22:42:11 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (89 lines)
We run lots of current through some of our PWBs. Let me see if I can take a
photo on that detail for power connections. Extremly tough connections.
/Inge


-----Ursprungligt meddelande-----
Från: TechNet [mailto:[log in to unmask]] För Gary Crowell
Skickat: den 20 september 2007 22:17
Till: [log in to unmask]
Ämne: Re: [TN] Screwing to a PWB

Keystone makes standoff screw terminals that can be soldered to the pcb.
Amp/Tyco has some similar press-fit terminals.  You can get more current
thru the press-fit terminals (no thermal relief on the pads required)

AMP Powertap http://tinyurl.com/35oa5f

Gary Crowell
Micron Technology 

> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Bloomquist, Ken
> Sent: Thursday, September 20, 2007 1:52 PM
> To: [log in to unmask]
> Subject: [TN] Screwing to a PWB
> 
> We have some large lugs that we need to screw to a PWB. Several ideas
> have been floated but I'm concerned about torquing against 
> the pads of a
> PTH on a multi layer board.
> 
> This is in a high vibration environment so they need to stay in place.
> Because of the units design the wires cannot be soldered or the lugs
> cannot be soldered or screwed directly to the PWB. They need to be
> elevated on a standoff of some kind. One option was to screw the male
> threaded end of a standoff to the board and then screw the lugs to the
> other side of the standoff.
> 
> It seems like I remember some where in my gorilla bag that screwing
> standoffs or anything else that needs a good electrical path was not a
> good idea. These wires are 16 awg and there are four going to 
> each lug.
> 
> Anybody want to chime in on this?
> 
> KennyB
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with 
> following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send 
> e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail 
> to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: 
> http://listserv.ipc.org/archives
> Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for 
> additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2