Thanks, Mike,
another intelligent add to the discussion. The guys who 'invented' the
method of 'plasma oxidize' are both PhDs, one in Solid State Technology,
the other in Laser Physics. They performed tests with some substrates in
that they exposed these to damp environment plus voltage after the
oxidizing. As there was no silver migration, they had proven the idea.
With all respect, I'm not at all convinced. Migration and dendrite
formations are often hard to create in the lab. The reality life in the
field is different, as we all know. Testing a couple of samples is not
comparable with thousands of substrates in all kinds of situations.
Furthermore, oxidizing a few nanometers of silver on the silver epoxy
dot's surface does not inhibit possible migration paths from the
underlying millions of silver flakes. I think the whole idea is
preposterous, or I'm not learned enough to get it.
Thanks all for the contributions
/Inge

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Mike Fenner
Sent: den 3 september 2007 17:32
To: [log in to unmask]
Subject: Re: [TN] Plasma "oxidation"

I'm confused by this, probably because I'm not knowledgeable on plasma
cleaning. But so far as I understand this area, the principal uses of
plasma are
- ash off surface contamination to get a clean surface, Or
- it can be used to impregnate or  burn surfaces to make them 'active'
(eg to make PTFE bondable with adhesive) It depends (!) on the type of
plasma and energies used.

This seems to be a confusion of these two functions. Oxidising epoxy
would make a carbon rich layer, oxidizing silver would make silver
oxide, both AgO and C are conductive so we have  weakly conductive
substrate.
This is a powered device so we have some volts,. The only missing item
for Ag migration is a little damp.

Altogether: not a recipe for high reliability. Or did I miss something?





Regards 

Mike

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Hernefjord Ingemar
Sent: Friday, August 31, 2007 9:53 AM
To: [log in to unmask]
Subject: [TN] Plasma "oxidation"

 
Yup. Strange title. I've been asked about a strange process, which one
was introduced without my knowledge, and I'm going to throw it out. But
I thought of consulting TN before. This is the case:

LTCC substrates are silver epoxy dispensed for chip mounting. In order
to avoid risk for silver migration, a guy invented plasma "oxidation",
i.e. he use a plasma cleaner, runs Argon with 6% Oxygen for a couple of
minutes on mounted substrates. The silver epoxy dots become blackish
because of oxidation, and oxidized epoxy is meant to minimize risk for
silver migration. The oxide is of course just nanometer thick. The guy
worked at a wafer manufacturing plant and had experience of cleaning
procedures.

I mean that this process is nonsense. If humidity gets in and condense
on the substrate, and if the electric field is high enough, and if there
are salts or contaminations, there is still enough silver to start
migration. Oxidation of the silver dot's surface is meaningless. Anyone
heard of such a strange process? Plasma operation on mounted LTCC
substrates is foreign to me, I want it out.

TrikeMan?

Inge

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------


***This email, its content and any files transmitted with it are
intended solely for the addressee(s) and may be legally privileged
and/or confidential. If you are not the intended recipient please delete
and contact the sender by return and delete the material from any
computer. Any review, retransmission, dissemination or other use of, or
taking of any action in reliance upon, this information by persons or
entities other than the intended recipient is prohibited. 

Messages sent via this medium may be subject to delays, non-delivery and
unauthorized alteration. This email has been prepared using information
believed by the author to be reliable and accurate, but Indium
Corporation makes no warranty as to accuracy or completeness. In
particular, Indium Corporation does not accept responsibility for
changes made to this email after it was sent. Any opinions or
recommendations expressed herein are solely those of the author. They
may be subject to change without notice.***

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2