Depends on what your contract identified as the order of precedence.  

We mandate compliance with the workmanship requirements of IPC/WHMA-A-620,
IPC-A-610 and J-STD-001, as well as some additional; criteria we mandate.  

In event of a conflict between our mandated criteria and the IPC standards,
we state that our criteria takes precedence.  

In event of a conflict between IPC documents (and just like Ripleys believe
it or not, there are some), we require that the more restrictive IPC
requirement apply.  

Normally, we do not allow manufacturer workmanship requirements to take
precedence over IPC because, it may be that the manufacturer document is in
error because it did not duplicate the requirement, or otherwise, the
manufacturer document was not based on the latest revision of the IPC
standard.  However, we do allow the manufacturer document to take precedence
only in event it is submitted for our approval.  That way we have control
over its contents and can assure it conforms to the IPC standards and our
add on requirements.


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Bob Arciolla
Sent: Thursday, August 23, 2007 10:08 AM
To: [log in to unmask]
Subject: [TN] Fw: question regarding IPC standard

Hi all,
A question came up here yesterday regarding what has precedence in regard to
quality issues. Some say IPC 610 would over company criteria and some visa
versa. The question came up noting that it is a standard and cannot be
changed. Others said it is that companies can vary from the standard if they
choose. Help.. who is right here??

Thanks, Bob

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2