Eureka better have been his wife's name or he really would have been in
hot water.
Dewey
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Hernefjord Ingemar
Sent: Tuesday, August 28, 2007 11:03 PM
To: [log in to unmask]
Subject: Re: [TN] Baking out board moisture
Werner,
then why a problem. If Tg180 has half the water absorption of Tg130,
and you double the water pressure, won't the result be the same? If
Archimedes fills his bathtub in a way, that the water rise equals the
upper edge when he jumps in, and next time doubles the size of the
bathtub but jumps in together with his wife, won't it be the same? It
seems to me that he shouted 'Eureka' twice.
Inge
________________________________
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: den 28 augusti 2007 22:22
To: Hernefjord Ingemar; [log in to unmask]
Subject: Re: [TN] Baking out board moisture
Hi Inge,
The problem is not a higher moisture absorption with higher Tg, but the
doubling of the vapor pressure for the same moisture absorption going
from 220 to 260C.
Werner
**************************************
Get a sneak peek of the all-new AOL at
http://discover.aol.com/memed/aolcom30tour
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|