Hi Brian

It depends! There, got that in before Doug!

If the coating has a solvent or water base, then you will experience  
some drying and curing issues, maybe cracking as well.

If you go too fast, you drive the solvent out too fast for the film  
to form properly.

With some coatings, the hot surface might help matters. Warm surfaces  
definitely aid tip and edge coverage.

What is the coating, how thick and what is the surface temperature  
you are applying to?

Kindest regards,

Graham

[log in to unmask]



On 11 Jul 2007, at 21:26, Brian A. Stumm wrote:

> I'm looking for comments from those who have any experience in  
> attempting
> to apply conformal coatings to a hot assembly. By hot I would say  
> equal to
> or less than the recommended cure temperature for the particular  
> coating.
> I'd be interested in any positives or negatives to having a hot  
> assembly
> while applying the coating. Thanks.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail  
> to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to  
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/ 
> archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp? 
> Pageid=4.3.16 for additional information, or contact Keach Sasamori  
> at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2