Hi,
 
We have an application where we are using a QFN/SON package that has one
large exposed pad at the bottom of the package.  In order to ensure good
electrical characteristics and thermal protection, the chip manufacturer
recommends a thermal pad via design.  The recommendation is to use 6
via's within the large pad placed on a 1.0mm pitch to help facilitate
the thermal relief.  In addition, they suggest 0.3mm diameter drill
holes.  There are several suggestions on what one would do to these
via's to reduce the exposure of excess voiding during the reflow
process.  One suggestion is via tenting top side only, second suggestion
is via tenting bottom side only, third suggestion is via plugging from
the bottom side, and finally the fourth suggestion is via encroached
from the bottom.
 
As I look at these suggestions,  I would probably utilize the via
tenting top side only, since this would probably result in smaller
voids, but one of the risks is a hindrance of proper paste printing.
Options 2 and 3, I would think that there would be an increased in out
gassing and voiding.  The fourth option would cause reduced voiding, but
could cause a lower standoff of the package, causing improper soldering
conditions.
 
 
Anyone have a thoughts/experience on how to handle this type of
application?
 
Best Regards,
 


Jim West
Engineering Manager
Nexergy Inc.
www.nexergy.com
tel: (614) 351-6216
fax: (614) 324-1979



This email message and all attachments transmitted with it are intended solely for the use of the addressee(s) and may contain legally privileged, protected or confidential information. If you believe that you have received this message in error, please notify the sender immediately by email reply and please delete this message from your computer and destroy any copies.

--------------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2