Thanks!!! My brother. 



And the IPC TM 650 is available on IPC website. The CAF relevant test

is in 2.6.25. It is free. 







 



 



>>> 华荣双 <[log in to unmask]> 2007-7-26 12:17 >>>

Dear Jason:

    PCB板两线之间的绝缘阻抗是20M,可用阻抗测试机测,但两过孔之间似未见到相关标准。孔距本厂要求对ANTI

CAF料为12mil,对普通料为14mil,各PCB厂可能不一样,主要与钻孔质量及Desmear有关。关于CAF测试,IPC

TM650上有测试方法,可查阅。

一般湿热试验后,孔壁会吸湿,水的介电常数比基材小,电阻当然会降低。

RS Hua



-----原始邮件-----

发件人: TGAsia [mailto:[log in to unmask]]代表 Li Ruijuan

发送时间: 2007年7月26日 11:24

收件人: [log in to unmask] 

主题: [TGA] 请教







大家好! 



请问关于PCB板过孔之间的绝缘阻抗要求是什么,测试条件呢,对孔距\孔径有没有要求?另外,如果验证是否会有CAF缺陷,实验条件怎样规定,谢谢 



孔间距很大,湿热试验后孔间绝缘电阻却减小很多,可能是什么原因呢? 







--------------------------------------------------------



ZTE Information Security Notice: The information contained in this mail

is solely property of the sender's organization. This mail communication

is confidential. Recipients named above are obligated to maintain

secrecy and are not permitted to disclose the contents of this

communication to others.



This email and any files transmitted with it are confidential and

intended solely for the use of the individual or entity to whom they are

addressed. If you have received this email in error please notify the

originator of the message. Any views expressed in this message are those

of the individual sender.



This message has been scanned for viruses and Spam by ZTE Anti-Spam

system.




ATOM RSS1 RSS2