TECHNET Archives

June 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Dwight Mattix <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Dwight Mattix <[log in to unmask]>
Date:
Tue, 5 Jun 2007 07:43:58 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (67 lines)
You need to get some x-sections going.  Might be more conventional plated 
hole wall defects in play.

However, on the subject of EM320.
Are you using EM320 (dicy cured) of EM320LF (phenolic cured for pb free assy)?

There's a big difference in survivability between these two similarly named 
materials.  I strongly recommend use of the EM320LF if you're soldering at 
Pb-free temps.

We've had good luck with EM320LF in several designs we've converted to 
Pb-free in this thickness range..  Designs have ranged from 1mm thick 2+4+2 
stacked uVia to 0.093" single lam plated through hole 10 layer.  They've 
done well through 1000+ cycles (150C) of IST after 3x, 6x, 9x IST 
pre-conditioning at 260C (the uVia design went to 2000 cycles w/out failure).

dw


At 07:13 AM 6/5/2007, Tom Parkinson wrote:
>Tech Net & Designer Net
>
>Greetings. We are running into a situation on Lead Free processed PCBs.
>Failure mode is finding open vias during unit testing (fully populated).
>
>Boards are Tg170, Material type EM320, 0.063" thick boards.
>6 layers of 1 oz copper. ENIG 3~5u"
>
>Suspect vias go from top layer to bottom layer only.
>
>After running through reflow, we have found vias open. No visual signs of
>delamination, however when ohming out the via, if we press on the via we get
>continuity - thus we suspect the vias are opening during the process.
>
>Anyone out there having these problems, or information concerning this
>failure mode?  Z-expansion failure?
>
>
>Tom Parkinson
>Quality System Manager - CIT
>WinTronics, Inc.
>Phone: 724-981-5770 - extension 235
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to 
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to 
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
>for additional information, or contact Keach Sasamori at [log in to unmask] or 
>847-615-7100 ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives