TECHNET Archives

June 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Tempea, Ioan" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Tempea, Ioan
Date:
Tue, 26 Jun 2007 10:57:52 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (64 lines)
Basically landpatterns too widely spaced to avoid tombstoning.

Ioan

-----Original Message-----
From: Stadem, Richard D. [mailto:[log in to unmask]]
Sent: Tuesday, June 26, 2007 10:01 AM
To: TechNet E-Mail Forum; Tempea, Ioan
Subject: RE: [TN] SMT placement test PCB


Just curious, why did you find the Practical and Topline pwbs
unsatisfactory? 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Tempea, Ioan
Sent: Tuesday, June 26, 2007 8:56 AM
To: [log in to unmask]
Subject: [TN] SMT placement test PCB

Dear colleagues,

I am pondering the necessity of having a custom PCB designed, PCB that
would serve for periodical testing of the placement of our machines. We
have Fuji CP6 and IP3, just FYI as I don't think the board should be
speciffic to a machine in particular.

I am wondering if any of you felt the need of having a special PCB to
perform this, or you find the glass board for IP and the regular Fuji
test board sufficient?

I have checked the available boards from Practical and Topline and find
them unsatisfactory when it gets to 0402 and 0201 landpatterns.

If you would order a special PCB, how would you use it? What components
should it be there?

Thanks,

Ioan

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2