I hate the "B" word because it describes an optical appea
David,



I hate the "B" word because it describes an optical appearance rather

than a failure mechanism.  I've heard the "B" word as well as terms like

"weak Nickel" and "Black Line Nickel" used many times to describe ENIG

failures.  The reason I don't like these terms is because they are

adjectives to describe what one thinks they see and don't describe the

failure mechanism that causes the brittle interface failures.  We use

ENIG on an old telecommunications legacy product because it wouldn't be

profitable to do any engineering evaluations to qualify another surface

finish.  However, since the root cause of the ENIG solder joint failure

mechanism has never been understood or resolved to the point where one

can turn it on or off, we avoid the use of ENIG surface finish on all

new products.  Even though the suppliers of ENIG chemistry have done a

great job of monitoring their chemistry and educating board shops on the

proper controls to reduce the occurrences of brittle solder joint

failures they haven't been able to eliminate these type of failure.

Ingemar is one of the few people I know of on TN that not only has a

great understanding of solder joints but appreciates the process control

details one needs to follow in PCB fabrication as well as PCBA to avoid

un-reliable solder joints.  His current problem (i.e., not being able to

understand the failure mechanism or predict when it is going to happen)

is the major reason we avoid the use of ENIG surface finish.  



Let's just say Ingemar does a cross section and confirms that there is

"mud flat" nickel grain boundary attack, what does he do on Monday?

Your advice about having a beer because it is Friday and not worrying

about this until Monday only will help this weekend but come Monday what

does he do.  I assume that he's already using a "good" board shop and a

"Good" ENIG chemistry.  I know what we did and it worked for us but as

an engineer I'd really like to what the ENIG failure mechanism is and

how to avoid it.



Regards,

George

George M. Wenger

Andrew Corporation Wireless Network Solutions

Senior Principal FMA / Reliability Engineer

40 Technology Drive, Warren, NJ 07059

(908) 546-4531 [Office]  (732) 309-8964 [Cell]



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of David D. Hillman

Sent: Friday, May 04, 2007 4:45 PM

To: [log in to unmask]

Subject: Re: [TN] Metalurgists, need assistance



Hi folks and thank you Steve for being "TechNet Picture Central"!  Sorry



but just to warn everyone but I am going to use the "B" word shortly.

Inge 

- take a close look at picture 4. As Werner pointed out the gold is 

non-wetting the nickel  in number of locations. What really jumped out

at 

me is that "mud flat" appearance on some of the nickel surface regions -

a 

"mud flat" appearance is a classic indication of black pad! I recommend 

you complete a cross-section to confirm that you have nickel grain 

boundary attack. 



But since it is Friday, go have a beer and worry about this on Monday!



Dave Hillman

Rockwell Collins

[log in to unmask]









Steve Gregory <[log in to unmask]> 

Sent by: TechNet <[log in to unmask]>

05/04/2007 01:45 PM

Please respond to

TechNet E-Mail Forum <[log in to unmask]>; Please respond to

Steve Gregory <[log in to unmask]>





To

[log in to unmask]

cc



Subject

Re: [TN] Metalurgists, need assistance













Hi Inge!



Got your pictures posted. Took me a bit, I was swapping our wave

solderpot from 63/37 to HMP. Done now. I'm getting quicker, I can do it

in 20-minutes now. Took me about 45-minutes when I first did it...



Anyways, here's the links:



http://stevezeva.homestead.com/files/Pic1.jpg

http://stevezeva.homestead.com/files/Pic2.jpg

http://stevezeva.homestead.com/files/Pic3.jpg

http://stevezeva.homestead.com/files/Pic4.jpg

http://stevezeva.homestead.com/files/Pic5.jpg

http://stevezeva.homestead.com/files/Pic6.jpg



-Steve-



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Hfjord

Sent: Friday, May 04, 2007 12:22 PM

To: [log in to unmask]

Subject: [TN] Metalurgists, need assistance



Have an issue with (randomly) lifted FPGA leads.

Pic 1: good joint after pull test

Pic 2: ditto but high magnification

Pic 3: "rotten" joint after pull test

Pic 4: ditto but high magnification

Pic 5: "rotten" cross section

Pic 6: ditto but high magnification



60Sn on ENIG, obviously a brittle region. Suspect Kirkendall voids, but

the pockets with zillions of Tin spheres (0.1 to 2 um in size) points at

insufficient peak temperature to make 100% melt and good solidifying. If

these little balls were Lead, I could understand, but they are Tin!

Never seen like. Any "quickhead" out there, need fast advice. 



Note: Pic 2, you can see the underlying board pad nickel as dark areas. 

An experienced analyst will hopefully recognize. No Phosphorous peaks!



My Friday headache.



Inge



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to [log in to unmask]: SET

Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the

posts: send e-mail to [log in to unmask]: SET Technet Digest Search the

archives of previous posts at: http://listserv.ipc.org/archives Please

visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for

additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to 

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to 

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at:

http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 

for additional information, or contact Keach Sasamori at [log in to unmask]

or 

847-615-7100 ext.2815

-----------------------------------------------------





---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to

[log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at:

http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional

information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815

-----------------------------------------------------





------------------------------------------------------------------------------------------------

This message is for the designated recipient only and may

contain privileged, proprietary, or otherwise private information.  

If you have received it in error, please notify the sender

immediately and delete the original.  Any unauthorized use of

this email is prohibited.

------------------------------------------------------------------------------------------------

[mf2]



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2