TECHNET Archives

May 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Scott Decker <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Scott Decker <[log in to unmask]>
Date:
Fri, 11 May 2007 14:25:34 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (183 lines)
I hope this doesn't foil Dewey's attempt at humor, he can really advance in epée-ic proportions if allowed.

Scott Decker
AKA: PadMasterson
Hypercom CAD
Ph:602-504-5344

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: Friday, May 11, 2007 2:08 PM
To: [log in to unmask]
Subject: Re: [TN] RF fences, oldering

He tried to steal some mustard in France..... 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Douglas O. Pauls
Sent: Friday, May 11, 2007 3:49 PM
To: [log in to unmask]
Subject: Re: [TN] RF fences, oldering

Certainly learned your lessons better than Dewey.  The last time he
tried to fence something, he got arrested.... or so I heard......

Doug Pauls




"Whittaker, Dewey (EHCOE)" <[log in to unmask]> Sent by:
TechNet <[log in to unmask]>
05/11/2007 03:33 PM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to "Whittaker,
Dewey (EHCOE)" <[log in to unmask]>


To
[log in to unmask]
cc

Subject
Re: [TN] RF fences, oldering






There's no foiling you. You have learned your fencing lessons well. All
points well taken.
Dewey

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: Friday, May 11, 2007 1:18 PM
To: [log in to unmask]
Subject: Re: [TN] RF fences, oldering

You can probably use tin-plated steel for the fence, but you may not
want to. The tin can certainly be plated directly to the steel, but it
would have to be of such thickness that there would be no risk of
complete dissolution into the solder, else you have nothing to solder
to. I am not sure if this is practical or possible. I am assuming you
want a wet-joint connection (fully-soldered) along the ground plane on
the board, not a mechanical clip or snap-and-twist.
Secondly, Kester recommends against using tin-plated steel or brass for
shielding fences. Tin-plated steel is plated at the mill and then after
the fences are cut out you have a lot of exposed edges that corrode
quickly. You need slightly higher temperatures to solder to tin-plated
steel, and when you already have a high-mass steel fence the soldering
becomes so difficult that after repeated attempts there is no more tin,
and guess what happens then? 
I would use a .16 micron nickel barrier covered with Sn97.6Cu2.4 if I
had to use steel fences. I personally prefer nickel-plated brass. Have
the fences cut first and then nickel plated to cover all exposed basis
metal.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Tempea, Ioan
Sent: Friday, May 11, 2007 12:02 PM
To: [log in to unmask]
Subject: [TN] RF fences, oldering

Hi everybody,

since I had no answer to my question regarding the required thickness of
the Cu layer on top of a steel fence, I try to reformulate.

Can a fence be Sn plated steel only, with no Cu or Ni in between? Would
this solder, since Fe is practically insoluble in Sn, so there will be
no IMC?

Thanks,

Ioan

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask]
or 
847-615-7100 ext.2815
-----------------------------------------------------


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2