Hi 'Netters,
I am coming across some horror stories with ENIG plating inside vias, with 
the ENIG fracturing during solder-T excursions and then digging into the ED-Cu 
causing stress concentrations and ED-Cu fracturing. My own fatigue ductility 
testing of ED-Cu foil with ENIG plating shows much reduced fatigue life. This 
is, of course of no consequence on a soldering pad, but inside the via, 
particularly with the much higher solder-T's required for SAC, this turns out to be a 
real problem.
I would appreciate hearing about other experiences, and how people are 
handling this.

Werner



**************************************
 See what's free at http://www.aol.com.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2