Kevin, 

Can't tell you where to look can only tell you what we have used for the
last 30 years.  0.010" over lead diameter for hand inserted parts and
0.014" over lead diameter for auto-inserted parts.  Actually, the
insertion machine manufacturers would prefer a couple of extra thousands
of an inch, but we seem to do fine at fourteen.

Gary Camac
Senior Mfg. Eng.
DICKEY-john Corp. 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kevin Glidden
Sent: Thursday, May 10, 2007 8:05 AM
To: [log in to unmask]
Subject: [TN] PTH sizing

Where does one look for basic guidelines on PTH sizing (with regard to
lead size, pcb thickness, & min-nom-max finished sizings) Thanks,
 
 
Kevin Glidden
Manufacturing Engineer
Luminescent Systems Inc.
 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2