Hi All, 
Vias should never be specified in terms of finished hole size (there is no 
functional need for any specific finished hole diameter),   but in terms of 
drilled hile diameter, because that determines all kinds of things important to 
the reliability of the via interconnect structure.

Werner



**************************************