We use a Metronolec ST-60 with good success. They have a pretty good
website with lots of details and also do contract testing. You can find
them at Solderability Testing Inc. if you Google it. 

The most success we've had with wetting balance testing is as comparison
testing, with a known good lot against a suspect lot.  Typically rather
easy to show a statistical difference, if there is one.  Also we inspect
the dipped parts for the required 95% wetting, and then use the charts
to numercially support the visual case.   Found that this is an easier
way to go about it since J-std-002 had a specific visual dip & look
wetting requirement, whereas the wetting balance is a "Test Without
Established Accept/Reject Criteria".


Rich K / GTS
847-621-7310
 
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Tempea, Ioan
Sent: Monday, April 23, 2007 10:13 AM
To: [log in to unmask]
Subject: [TN] solderability testing

Hi Technos,

I need to setup a sort of solderability testing process.

J-STD-002 is pretty clear, but I would like to know how are you set up
for the job. Mainly I would like to be able to make a decision on dip
and look OR wetting balance?
What kind of equipment are you using?
How to make the tests less of a black magic and more of a repeatable
process, with easy to interpret results?

Thanks,

Ioan


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2