Subject: | |
From: | |
Reply To: | (Combined Forum of D-33a and 7-31a Subcommittees) |
Date: | Wed, 18 Apr 2007 14:27:07 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Thanks, Werner
Test condition B is 260C with the appropriate tolerances
Susan
-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Wednesday, April 18, 2007 2:13 PM
To: Susan Hott; [log in to unmask]
Subject: Re: [IPC-600-6012] Thermal Stress Testing for 6016 and 6012
Hi Susan,
I certainly would strongly lean towards IPC-6018 (HDI), para 3.6.1.
However, even this needs changing to 260°C.
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com
**************************************
See what's free at http://www.aol.com.
|
|
|