Especially since the Sn96 starts out with 4% noble metal.  





Regards, 

George 

George M. Wenger 

Senior Principle FMA / Reliability Engineer 

Wireless network Solutions 

Andrew Corporation, 40 Technology Drive, Warren, NJ 07059 (908) 546-4531

[log in to unmask] 





-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of David D. Hillman

Sent: Friday, March 30, 2007 8:25 AM

To: [log in to unmask]

Subject: Re: [TN] Soldering using Sn96



Happy Friday Jim! This is only a guess but one possible reason for such

a recommendation is the potential to have solder joint integrity

degradation due to gold embrittlement. A high tin content solder alloy

and gold surface finishes do not necessarily mean a gold embrittlement

situation but it would be on aspect of a solder process that would need

to be kept in mind.



Dave Hillman

Rockwell Collins

[log in to unmask]







 



             "Marsico, James"



             <James.Marsico@ED



             OCORP.COM>

To 

             Sent by: TechNet          [log in to unmask]



             <[log in to unmask]>

cc 

 



 

Subject 

             03/30/2007 06:46          [TN] Soldering using Sn96



             AM



 



 



             Please respond to



              TechNet E-Mail



                   Forum



             <[log in to unmask]>



             ; Please respond



                    to



             "Marsico, James"



             <James.Marsico@ED



                OCORP.COM>



 



 











Technetters:







I happened to come across a solder chart from the Indium Corporation and

noticed that they do not recommend using Sn96 solder on gold-plated

surfaces.  Can anyone elaborate on this?







Jim Marsico



EDO Corporation



1250 New Horizons Blvd.



North Amityville, NY 11701



631-630-5079



[log in to unmask]









---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to

[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing

per day of all the posts: send e-mail to

[log in to unmask]: SET Technet Digest

Search the archives of previous posts at:

http://listserv.ipc.org/archives Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16

for additional information, or contact Keach Sasamori at [log in to unmask]

or 847-615-7100 ext.2815

-----------------------------------------------------



---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0 To

unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or

(re-start) delivery of Technet send e-mail to [log in to unmask]: SET

Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the

posts: send e-mail to [log in to unmask]: SET Technet Digest Search the

archives of previous posts at: http://listserv.ipc.org/archives Please

visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for

additional information, or contact Keach Sasamori at [log in to unmask] or

847-615-7100 ext.2815

-----------------------------------------------------



------------------------------------------------------------------------------------------------

This message is for the designated recipient only and may

contain privileged, proprietary, or otherwise private information.  

If you have received it in error, please notify the sender

immediately and delete the original.  Any unauthorized use of

this email is prohibited.

------------------------------------------------------------------------------------------------

[mf2]



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2