David Greig <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, David Greig <[log in to unmask]>
Date:
Fri, 2 Mar 2007 17:35:19 -0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (98 lines)
Richard,

For TI's 0.8mm lead free BGA's, I know from my own experience that a 0.38/0.40mm NSMD land gives better results, rather than
their suggested 0.35mm. 
This is for 532 ball DSP's that I've been designing in recently.

Best Regards
 
David Greig

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stadem, Richard D.
Sent: 02 March 2007 17:09
To: [log in to unmask]
Subject: Re: [TN] BGA footprint

Hey, Kim, thanks!
This is good info. To make it easier to find for others who may be interested, I have included a direct link to the document
with the pad design information for a .5mm pitch design. Look at the Reliability section also. Lots of good information.
http://focus.ti.com/lit/an/ssyz015b/ssyz015b.pdf 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Haynes, Kim
Sent: Friday, March 02, 2007 10:42 AM
To: [log in to unmask]
Subject: Re: [TN] BGA footprint

Check www.ti.com and enter microstar in the text search box.  There are several papers on small pitch BGA devices and the PCB
designs to make them usuable.  The thermal issues may also be important in a CSP.
Good luck,
Kim

________________________________

From: TechNet on behalf of Bob Perkins
Sent: Thu 3/1/2007 6:36 PM
To: [log in to unmask]
Subject: [TN] BGA footprint



Hi

I am working on a new board with a 0.5mm pitch BGA and I am wonder if someone can advise me on the footprint.

1) the datasheet says the solder ball is 0.3mm +/-0.05mm
2) IPC recommends to use 80% of ball diameter for the pad which would be 0.24mm
3) Would it be OK to use a 0.2mm pad? I am hesitant to go against recommended size without some corroborating documentation. The
reason I would want to use 0.2mm pad is to avoid using via-in-pad.

I am curious if IPC defines footprints based on what is good for manufacturing or is it simply theoretical?

Thanks
Bob

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with
following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of
all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with
following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of
all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To unsubscribe, send a message to [log in to unmask] with
following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send
e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC
web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at
[log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
--
Virus scanned by Lumison.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2