What is the URL address for goddard?

Vic,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Jeffrey Bush
Sent: Thursday, March 29, 2007 10:00 AM
To: [log in to unmask]
Subject: Re: [TN] IPC 6012 : Outgassing Criteria

Outgassing control is critical in space flight applications.  Materials
like laminate, masks and inks are tested for CVCM, WVR and TML and need
to meet certain levels to be used in space applications.  Outgassing can
interfere with optics, devices, etc as these elements have much greater
impact to the system in a vacuum.  Goddard publishes an 1124 data
manual, that you can get for no cost, listing the materials that have
already been tested.  You can use these materials in lieu of testing to
meet outgassing requirements.      

Jeffrey Bush
Director, Quality Assurance and Technical Support
VERMONT CIRCUITS INCORPORATED 
           76 Technology Drive - POB 1890 
              Brattleboro, Vermont 05302
                Voice - 802.257.4571 ext 37 
                    Fax - 802.257.0011
                       <http://www.vtcircuits.com/> 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lum Wee Mei
Sent: Wednesday, March 28, 2007 11:17 PM
To: [log in to unmask]
Subject: [TN] IPC 6012 : Outgassing Criteria

Hello,
 
I was reading this IPC 6012 when I come across Section 3.11.1 Outgassing
 
1. What actually is outgassing?
2. Why is outgassing critical for PCB?
3. As the PCB consist of so many processes and different materials go
into making it, where did the outgassing come from? 4. Is the criteria
mandatory for all Class PCB or only specified application?
5. If for only specific application, which application and why?
6. Come to think about it, can the outgassing come also from the coating
we use to seal the assembly?
 
Hope someone out there can share with me (novice) on this issue.
 
Thanks and regards,
Wee Mei

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2