TECHNET Archives

March 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Kane, Amol (349)" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Kane, Amol (349)
Date:
Wed, 28 Mar 2007 10:58:51 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (212 lines)
Dear Members,
I am trying to hand solder to a substrate that, I have been told is Ni plated Beryllium Copper with SnPb no clean process (it is actually for a battery termination). Are there special considerations involved when soldering to this substrate? I am having a hard time getting the solder to wet and stick to the substrate. It just balls up (doesn't stick) and refuses to form a bond. I have already tried cleaning the area with alcohol without success.

Any pointers/information that I am not aware of?

Thanks in advance,
Amol


 -----Original Message-----
From: 	TechNet [mailto:[log in to unmask]]  On Behalf Of Dehoyos, Ramon
Sent:	Friday, May 05, 2006 8:05 AM
To:	[log in to unmask]
Subject:	Re: [TN] PWB de-paneling

        Hi Sumx:
                   Drill holes, in the center of the joints forming a
line (tabs, become mouse bites). Holes should be made by a drill whose
diameter is smaller than the width of the joints with a gap of about 100
mills from adjacent sides. Bend the tabs 30 degrees towards one side and
then the opposite side, repeat till the tabs break off. Pull tab away
from the board. Note: do not bend to one side and pull. It is still
attached from one side and it will tear off glass fibers.  The bend must
be made to one side and to the other  and repeat till the tabs breaks
off. Pull tab away from the board and not in the direction the top or
bottom of the board is facing.
        Regards,
        Ramon
         

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Sumxplore
Sent: Thursday, May 04, 2006 10:47 AM
To: [log in to unmask]
Subject: Re: [TN] PWB de-paneling

I received a board without v-score but with 2 joints.Any idea how to
singulate it as the board with csp around 8mils from the edge or any
suggestion on how to redesign the boards for manufacturability.
Appreciate any input.Thanks in advance.

rgds
sumxp
----- Original Message -----
From: "Lee Parker" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, May 04, 2006 3:35 AM
Subject: Re: [TN] PWB de-paneling


> Victor
>
>
>
> Your boards may have been scored and the sheared or even punched when 
> they were depanelized. Punching is not uncommon in Asia even for 
> multilayer boards. In Asia the standard is what ever you specify. If 
> left unspecified all things are possible.
>
>
>
> Best regards
>
>
>
> Lee
>
>
>
> J. L. Parker Ph.D.
>
> JLP Consultants LLC
>
> (804) 779 3389
>
>
>
>
>
>
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Victor G. 
> Hernandez
> Sent: Tuesday, May 02, 2006 11:33 AM
> To: [log in to unmask]
> Subject: [TN] PWB de-paneling
>
>
>
> Fellow TechNetters:
>
>
>
>    What are some common acceptable practices for de-paneling PWB?
>
> I am more familiar with routing, which provides a smooth edge with 
> good
>
> quality control.
>
>
>
> I have observed some PWB from overseas suppliers with an edge that
>
> appears snapped with frayed edges.
>
> Is this in according with IPC Standards?
>
>
>
> Victor,
>
>
>
> ---------------------------------------------------
>
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>
> To unsubscribe, send a message to [log in to unmask] with following text

> in
>
> the BODY (NOT the subject field): SIGNOFF Technet
>
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
>
> Search the archives of previous posts at: 
> http://listserv.ipc.org/archives
>
> Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-615-7100 ext.2815
>
> -----------------------------------------------------
>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To 
> unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: 
> http://listserv.ipc.org/archives Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
> --
> Internal Virus Database is out-of-date.
> Checked by AVG Free Edition.
> Version: 7.1.375 / Virus Database: 268.3.1/291 - Release Date: 
> 3/24/2006
>
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------




CONFIDENTIALITY NOTICE: 
This e-mail, and any attachments, is for the sole use of the intended 
recipient(s) and may contain information that is confidential and 
protected from disclosure under the law. Any unauthorized review, use, 
disclosure, or distribution is prohibited. If you are not the intended 
recipient, please contact the sender by reply e-mail, and delete/destroy 
all copies of the original message and attachments. 
Thank you.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2