Ingemar,
It would seem that the SiC matrix should have been fully infiltrated
with the molten Al. Maybe you did not expect the blisters to be from
gas entrapment... What do you believe the source of the blistering to
be?
There was a time when someone was taking the AlSiC 'slug' and placing
that inside an aluminum casting - which could later be milled down, but
still leaving aluminum over the AlSiC slug.
From there plating was a snap.
Want me to dig out who it was that did it?
Steve
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Inge
Sent: Tuesday, March 20, 2007 3:39 PM
To: [log in to unmask]
Subject: [TN] AlSiC
Honoured Messieurs wet chemists,
have to make solderable finish on AlSiC substrates. Got copper plated
samples from manufacturer. We did usual 300 Centigrade blister test, and
as
expected, large blisters were created. Now, what suitable finish do you
recommend? Would like to try nickel sputter+electrolytic nickel+gold
flash,
but there may be wet chemistry for the adhesion layer instead of
sputtering
or thermal spray. There are tin plating methods too, but they seem not
to
be for soldering , but rather act as environment protection coatings.
Inge
-----------------------------------------------------
THE INFORMATION CONTAINED IN THIS E-MAIL MESSAGE AND ANY ATTACHMENTS SENT FROM GENTEX CORPORATION IS GENTEX CONFIDENTIAL INFORMATION INTENDED ONLY FOR THE PERSONAL USE OF THE INDIVIDUAL OR ENTITY NAMED ABOVE. If you are not the intended recipient, you are hereby notified that any review, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please immediately notify the sender by return e-mail, and delete this e-mail message and any attachments from your computer.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|