At 05:31 AM 3/12/2007, Marsico, James wrote:
>Hello Technet:
>
>
>
>Can anyone provide the pros and cons with using Nelco N4000-13EP vs.
>Isola FR408 with regard to PWB processing, reliability and performance
>for a high reliability application?


We have used a lot of both these materials extensively. Mostly in 
sequential lam, build up layer type products.

We don't use -13 anymore in stackups that have single ply uVia dielectrics 
and that require more than 2 laminations cycles. Too many delam problems in 
the past with -13.  -13 only has about 1/2 the innerlaminar bond strength 
of 408 and it requires extensive baking to protect that innerlaminar bond 
strength. I understand -13 is related to CE so do the math yourself.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2