TECHNET Archives

March 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Matt Kehoe-SIPAD Systems <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Matt Kehoe-SIPAD Systems <[log in to unmask]>
Date:
Mon, 12 Mar 2007 08:56:54 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (123 lines)
I can relate!!!!!!!!!!!!!

Matt Kehoe
SIPAD Systems Inc
"The Original Solid Solder Deposit"
360-C Winkler Drive
Alpharetta, GA. 30004
770-475-4576
770-475-1597 fax
www.sipad.com
[log in to unmask]
Please note, Matt Kehoe's E-mail has changed from
[log in to unmask] to [log in to unmask]
This new email is heavily filtered for spam. If your email is bounced,
forward the bounce back text to [log in to unmask] and your account will 
be unblocked.
Thank you for your patience in helping SIPAD Systems combat spam.
----- Original Message ----- 
From: "BADRI" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, March 09, 2007 11:21 PM
Subject: Re: [TN] Paste Volume, off contact vs non off contact


> Dear MK,
>
> We had this issue in one of our boards. Hell broke out during paste
> application in terms of sloppy and insufficient prints. Avoid them as much
> as possible.
>
> Badri
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Matt Kehoe
> Sent: Friday, March 09, 2007 10:31 PM
> To: [log in to unmask]
> Subject: [TN] Paste Volume, off contact vs non off contact
>
> We have been processing a family of boards for 3 years. No issues. New PCB
> Vendor and the boards suddenly will not print very well. Sloppy printing
> definition. Heavy heavy deposition.
>
> Closer inspection reveals that the soldermask is built up .0012-.0019 over
> the vias, preventing the stencil from gasketing. Vendor claims they are
> built to print.. Opinions?
>
> Pictures at ;
> http://www.sipad.com/ssiqa/3942vias.pdf
> http://www.sipad.com/ViasBuildup.pdf
>
> The question we are trying to answer is, if your boards came in with mask
> this thick over the vias would you feel confident in running them without
> modifing the stencil? Would you expect a significant increase in solder
> volume?
>
>
> mk
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
>
>
>
>
>
> Disclaimer:
> ===========
> This E-mail may contain privileged information and is intended solely for 
> the addressee. Any unauthorized use or dissemination of this message in 
> whole or in part is strictly prohibited. If you have received this mail by 
> mistake, please inform us immediately and delete this mail. Any 
> information expressed in this mail does not necessarily reflect the views 
> of Avalon Technologies (P) Ltd .
> Avalon Technologies(P) Ltd shall not be responsible nor liable for the 
> proper and complete transmission of the information contained in this 
> communication nor for any delay in its receipt or damage to your system. 
> Avalon Technologies(P) Ltd does not guarantee that the integrity of this 
> communication has been maintained nor that this communication is free of 
> interceptions or interference.We have taken precautions to minimize the 
> risk of transmitting software viruses, but we advise you to carry out your 
> own virus checks on any attachment to this message. We cannot accept 
> liability for any loss or damage caused by software viruses. Thank you for 
> your cooperation
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 15.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2