Jeffrey,
   I can't offer any info on a spec for you, but more of an idea if they
are concerned about this. Can they put some kind of guide in the panel
to align the board and hold it in position so as not to use the LED's as
alignment devices? Just a thought.
Later...

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of McGlaughlin, Jeffrey
A
Sent: Thursday, March 08, 2007 5:05 AM
To: [log in to unmask]
Subject: [TN] Post Assembly Bow and Twist

Technet and DesignersCouncil Gurus -

I have been asked by our mechanical engineering group to find out if
there is a standard or specification for post assembly flatness of
printed circuit cards.  This has never been an issue for functional
failure but a new design requires that a row of LEDs mate to a display
panel mask such that no light leaks from one LED cell to the next. Their
concern is that post assembly bow and twist will over stress solder
joints and board copper if they mechanically stress the cards by
pressing/pulling them flat to an assembly frame.  Can anyone direct me
to a standard or advise me on the maximum allowable bow and twist for
this type of situation?


Jeffrey McGlaughlin, CID 
Engineering Designer 
Battelle 
505 King Avenue 
Columbus Ohio 43201-2693 
(614)424-7582 Phone 
(614)458-7582 Fax 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2