Jim,

There is a reference to meniscus cracking in IPC-A-610D, section 9.3.




"West, Jim" <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]>
03/07/2007 10:12 AM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
"West, Jim" <[log in to unmask]>


To
[log in to unmask]
cc

Subject
[TN] Lead coating meniscus cracking






Hi,
 
I'm looking for the IPC standard that defines allowable or not
allowable, meniscus cracking that extends down from the body to the
leads.  Can you have some cracking of the meniscus that covers the leads
of a component?  Is there a standard that I can reference?  Due to the
requirements of your application, we are forced to bend the leads of the
component next to where the meniscus stops which sometimes causes
cracking.
 
Thanks,
 


Jim West
Engineering Manager
Nexergy Inc.
www.nexergy.com
tel: (614) 351-6216
fax: (614) 324-1979



This email message and all attachments transmitted with it are intended 
solely for the use of the addressee(s) and may contain legally privileged, 
protected or confidential information. If you believe that you have 
received this message in error, please notify the sender immediately by 
email reply and please delete this message from your computer and destroy 
any copies.

--------------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2