DESIGNERCOUNCIL Archives

March 2007

DesignerCouncil@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Sender:
DesignerCouncil <[log in to unmask]>
X-To:
Designers Council Forum <[log in to unmask]>
Date:
Mon, 26 Mar 2007 14:04:03 -0800
Reply-To:
"(Designers Council Forum)" <[log in to unmask]>, JaMi Smith <[log in to unmask]>
Subject:
MIME-Version:
1.0
Content-Transfer-Encoding:
7bit
Content-Type:
text/plain; charset="iso-8859-1"
From:
JaMi Smith <[log in to unmask]>
Parts/Attachments:
text/plain (164 lines)
ARRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR
RRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR
RRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR
RRRRRRRRRRRRRRGGGGGGGGGGGGGGGGGGGGGGGH!!!!!!!!!!!!!
(Very Long and Loud Primal Scream)

Fine Matthew, do it any way you want to . . .

Just don't call it standardized . . .

Just don't call it IPC-7351 compliant . . .

Just don't cry when someone else works on a revision to one of your
Design(s) in the future, and calls you a "stupid moron and a ****ing idiot"
and the worst Designer that they have ever run into because you "did it
backwards" for some stupid personal reason, and caused untold screwups on
some future production run.

You are going to do whatever the hell you want, in spite of what anyone
else, or what any standards, are going to say, so just go ahead and do it,
and stop trying to convince anyone else here in the forum that your are
right, because you are not - you are wrong - so go ahead and make your
boards the way that you want too, but mark my word, they will come back and
bite you in the a** a few years down the road, and all you will be
remembered as is the stupid Designer that screwed things up because he was
too stubborn and wanted to do it his way and wouldn't play according to
Hoyle.

And by the way, your successor, who will inherit your Designs after you
retire or move to another company, >>>>WILL<<<< "use [your] CAD package
(Cadstar) to create the pick & place file." - which will of course be all
****ed up, but he or she will not realize that until after a production run
has been made with your ****ed up Cadstar Pick and Place file because you
were to stubborn to do it right the first time.

You could have started a new Footprint Library and Schematic Symbol Library
and fixed the rotation of all of the components involved and redefined pin
numbers, etc., in one tenth of the time you have already spent writing about
it here in the forum. We are really only talking abour a couple of
components here now (you could add and fix others as you go).

Quit bitching about it here and just do what you are going to do.

I can't leave off here without specifically responding to part of what you
said below:

> IMO it is incapable of generating an accurate P&P file that includes all
> the data. (panel size, fiducials etc). Also component rotations change
> depending upon the supplier as it seems that not all suppliers follow the
> same standard.

If you would CORRECTLY DESIGN your components FOR the P&P file,
you WOULD have all of the CORRECT data in the P&P file. Panel size has
absolutly nothing to do with individual components or their footprints, as a
panel is usually built up as a "step and repeat" of individual boards, and
any "pick and place" machine out there today can compensate for "step and
repeat", including any necessary "rotation". Fiducials are not necessaruly a
problem, since they are generally seperately placed from the component, and
if they are critical to the component and it's rotation, then they can be
made
part of the component footprint itself.

As for the last sentance above, respecting changing rotations or
non-standard component rotation. THIS IS THE EXACT REASON WHY YOU
SHOULD FOLLOW THE COMPONENT ROTATION ADOPTED BY
IPC-7351, SO THAT COMPONENT ROTATION IN THE DESIGN WILL BE
STANDARDIZED, AND SO THAT >>>ANY<<< MANUFACTURING
ENGINEER CAN ADAPT >>>ANY NON-STANDARD<<< COMPONENT
ROTATION TO >>>ANY DESIGN<<< .

Sorry if it seems as if I am yelling at you - because I am !

JaMi

PS. Yes, it is true that some manufacturers do not follow ANSI/EIA-481 when
it comes to packaging components in "tape and reel" for "pick and place"
machines, but more and more are, and month by month the component
manufacturing industry is conforming and coming into line with the existing
standards, which is all the more reason why you should.

=====================================================
=====================================================

----- Original Message ----- 
From: "Matthew Lamkin" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, March 21, 2007 7:23 AM
Subject: Re: [DC] Footprint standards for Polarized components (Diodes)


Thanks for that Jack, the reasons in that document are exactly why I do NOT
use my CAD
package (Cadstar) to create the pick & place file.

IMO it is incapable of generating an accurate P&P file that includes all the
data.
(panel size, fiducials etc). Also component rotations change depending upon
the supplier
as it seems that not all suppliers follow the same standard.

I prefer to use GC-Place, using the panel data returned (for approval) from
my board manufacturer
prior to plotting, using the pads & an assembly drawing layer & a BOM file
makes it far more accurate & gets the rotations correct regardless of
whatever pin 1
is within Cadstar.

However, as said - I am using a legacy library and cannot go changing all
polarized components
to use pin 1 as Cathode etc as it will then affect future mods to older
boards.

So like I said, pin 1 is not that much of an issue with me.

Thank you,
Matthew Lamkin


----------------------------------------------------------------------------
------------------------------------------------------------------------ 
This email, its content and any files transmitted with it are intended
solely for the addressee(s) and may be legally privileged and/or
confidential. If you are not the intended recipient please delete and
contact the sender on the telephone number +44-(0)1282-717171 or via email
return. Unless expressly stated otherwise, and subject to the disclaimer
below, this email does not form part of a legally binding contract or
agreement between the recipient and Protec Fire Detection Plc. (registered
no. 1170489). Registered Office: Churchill Way. Nelson. BB9 6RT. Lancashire.
United Kingdom.
Messages sent via this medium may be subject to delays, non-delivery and
unauthorised alteration. This email has been prepared using information
believed by the author to be reliable and accurate, but Protec Fire
Detection Plc. makes no warranty as to accuracy or completeness. In
particular, Protec Fire Detection Plc. does not accept responsibility for
changes made to this email after it was sent. Any opinions or
recommendations expressed herein are solely those of the author.
----------------------------------------------------------------------------
------------------------------------------------------------------------ 

----------------------------------------------------------------------------
-----
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV
1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET
DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2