Yes,
Don't use them anywhere near a hipot tester or anything that could possibly
place a high voltage/current on an object you might accidentally touch. Goes
for heel or wrist straps, too. I have seen what this can do to a conductive
garment... It's not pretty. Just imagine yourself inside a dissipative smock
accidentally touching a high current source. The garment basically burns
itself up with you inside it!

As far as the need to have the smock connected to a direct path to ground
(flooring, etc.), I think I would need to see empirical data proving that it
makes a difference. I believe most smocks have enough surface area to
essentially bleed off or dissipate ESD charges before they can do damage. I
have a hard time believing that a dissipative smock with no direct ground
contact becomes a miniature capacitor...

Dale Ritzen
Quality Manager
Austin Manufacturing Services

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Dehoyos, Ramon
Sent: Thursday, February 01, 2007 9:27 AM
To: [log in to unmask]
Subject: [TN] FW: January 2007 ESD Systems.com Newsletter


                 Technetters:
                 Does any body have an opinion on grounded Smocks?
                Ramon

       

 

 

________________________________

From: [log in to unmask]
[mailto:[log in to unmask]] On Behalf Of Banana Jack
Sent: Tuesday, January 23, 2007 2:30 AM
To: Lusby, Jack R.
Subject: January 2007 ESD Systems.com Newsletter

 



 

Here is the latest ESD news from ESD Systems.com:

http://www.ESDSystems.com/Newsletters/v10issue1.html

 


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2