Fellow techs,
Receiving Inspection wants to temporarily remove MSDs from their protective
MBB to verify quantities, etc...and has asked me how long a MSD can be
safely left outside its protective, sealed MBB (under normal factory
conditions) before it must be rebaked. I plan on checking J-STD-033 for a
recommendation but would also like to know what the industry consensus about
this subject is and does its MSL affect it?
thanks
Joe
---------------------------------------------------