Hernefjord Ingemar <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Hernefjord Ingemar <[log in to unmask]>
Date:
Thu, 15 Feb 2007 08:17:25 +0100
Content-Type:
text/plain
Parts/Attachments:
text/plain (72 lines)
Madhusudhan,


I happened to get same question recently, my opinion is this:


The current limitation is not the balls, but the bondwires and the
copper lines from balls to chip. The current capacity of bond wires is:


             
I =  sq root(K/2P) x (Pi x D exp2/L)  x  sq root Delta T 

Where 

I = current in amperes
K = thermal conductivity in Watts/cm/Centigrade
P = resistivity in Ohm/cm
D = diameter of wire in cm
L = length of wire in cm
Delta T = temperature rise in Centigrades

Thus, a "normal" 0.001 inch (25um) gold bond wire will be able to carry
0.22 amperes. Just an example.

But noone designs a 25um BGA bond wire for such constantly high current.
At least what I think. Intermittantly, no problems, a 25um gold bond
wire can withstand 5 amperes during some milliseconds.

Likewise, you can calculate the current capacity for the balls, which
ought to have a magnitude higher current capacity.

Inge



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Madhusudhan Kulkarni
Sent: den 15 februari 2007 04:43
To: [log in to unmask]
Subject: [TN] BGA ball current

Hi,

what is the current rating of BGA ball(standard ball sizes).

Regards
Madhusudhan Kulkarni

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2