Hi Steve

Typical pad to mask clearances are 3mil, so that would leave only a 2mil strip of mask. 5mil is more commonly required by most
fabs. With round pads (BGA) the fab may accept it, but most would not countenance a 2mil strip if it's any length.

While it may be useful as a surface tension modifier, it's almost never present in the case of fine pitch parts where the
challenge of bridging is greater.


Best Regards
 
David Greig
______________________________
GigaDyne Ltd
5 Albany Business Centre
Gardeners Street
Dunfermline KY12 0RN
United Kingdom
t: +44 (0)1383 624 975
www.gigadyne.co.uk
______________________________

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
Sent: 12 February 2007 17:11
To: [log in to unmask]
Subject: [TN] LPI soldermask resolution

Mornin' All!
 
What kind of resolution should a LPI be able to give you? Specifically, LPI's should be able to give you a solder mask dam
between 20-mil pitch leads if you have 8-mils of space between the pads shouldn't it?
 
Thanks!
 
-Steve Gregory-

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with
following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send
e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC
web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at
[log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
--
Virus scanned by Lumison.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2