Surely that depends on the chemistry of the paste, the hold time before 
and after the component assembly and before reflow, as much as the RH?

Brian

Sklenar Vit (RBAU-AE/MFE3) wrote:
> Hi Techneters,
> 
> Please  is anybody aware or can you refer me to  any standard which
> addresses the maximum allowed  humidity  in electronic production  in
> order to prevent  microballs creation during reflow process?
> 
> Thank you fro your reply
> 
> Vit Sklenar
> Robert Bosch (Australia) Pty. Ltd. 
> RBAU/MF33 - VS, Process Eng.) 
> www.bosch.com.au 
> 
> Tel. +613 9541 7734
> Fax +613 9541 3909
> [log in to unmask] 2
>  
> 
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2