Hi John,
You have already received some good advice from Joe; here are some additional
inputs.
Barrel fractures typically occcur near the center of the vias at a prepreg
layer [higher z-CTE than laminate duue to higher resin content and less complete
cure].
Drilling: The first set could have been drilled with better/newer drills than
the second [this is unlikely, however] If this is the case you see very rough
hole walls and non-uniform barrel plating with lots of stress concentrations.
Plating: You Fab shop may be patch, rather than continuous, recondition the
plating solution. The consequence would be more dog-boning of the pating
[thinner in the middle] as well as lower strength and ductility of the copper
deposit.
Overall lower plating thickness may also be an issue.
Assembly: Higher peak reflow temperatures as well as a larger number of
solder process excursions promote via fractures.
From what you said, the via fractures were not complete [or the fracture
surfaces made contact] so bare board testing did not show anything. As soon as the
PCBs get warmer the fracture surfaces separate and an electrical open occurs.
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com
**************************************
AOL now offers free email to everyone.
Find out more about what's free from AOL at http://www.aol.com.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|