Hi Rich!

We use something called "Carroll Heavy Duty Lime Off 375". We've got a
Technical Devices Polyclean SMT 624. Here's a TDS:

http://www.carrollco.com/techsheet/375ts.pdf

It does a decent job getting rid of the build-up of water soluble mask
residues too. We only use it in our wash tank, the rinse side of the
cleaner normally stays pretty pristine. We'll pour in about 4-gallons of
the stuff in the wash tank and run the wash pumps for an hour or two to
clean the plumbing and nozzles good. Then scrub the sides of the wash
tank good with a brush, then drain and rinse everything well.

It's convenient for use because we have a cleaning supply company next
door to us that carries the stuff...

-Steve Gregory-

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Richard Kraszewski
Sent: Tuesday, January 09, 2007 11:24 AM
To: [log in to unmask]
Subject: [TN] Descaling of Water Wash Systems

To ~continue along this forum's recent cleaning track...

What are you using for de-scaling water wash systems?

Any recommendations would be appreciated. 

Rich K / GTS
  

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2