Ioan,
What John and the others were referring to is that the flux/solder paste
manufacturers have taken some of their no-clean products and given them
a little more "umph" for the reasons already stated.  The question
remains HOW MUCH?

If we are talking about a good solder paste from a good supplier to
which very little has been added, then there should be no difference.

If we are talking about a good solder paste from a good supplier to
which more than a little has been added, then there had better be
testing!

If we are talking about a good solder paste from a good supplier to
which a whole pile (good chemical description) has been added, then you
had better be cleaning!

If we are talking about a solder paste from a crappy supplier what are
you thinking!

Bev
RIM



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Tempea, Ioan
Sent: January 9, 2007 12:18 PM
To: [log in to unmask]
Subject: Re: [TN] Cleaning

So Bev,

LF residues really are more reactive? You seem to have done some
measurements.

Thanks,

Ioan

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Bev Christian
Sent: Tuesday, January 09, 2007 12:12 PM
To: [log in to unmask]
Subject: Re: [TN] Cleaning


John,
Not if they do their homework and do the proper testing to show that the
tweak in reactivity won't put them on dangerous ground.  That is why
there are tests like copper mirror, halide ion, British corrosion test,
SIR and electrochemical migration.
Bev
RIM

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of John Burke
Sent: January 9, 2007 12:02 PM
To: [log in to unmask]
Subject: Re: [TN] Cleaning

That's what I was thinking Brian...................8-)

With the change to lead free and the various "wetting" issues a lot of
people are using a more active flux if only to make the joints "look"
more
like 63/37 and as a result are having to use cleaning systems to remove
the
flux.

Of course the ones that do not remove the flux will find out eventually
why
they should have done!!

John

 
 
John Burke
 
(408) 515 4992

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------



---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2