The thickness alone is only part of the equation leading to
embrittlement. The total volume of gold as a percentage by volume within
the resultant solder joint is the critical factor. There is a lot of new
work that shows anytime you increase the gold content of a solder joint
by more than 1%, the chances of having gold embrittlement greatly
increases. So a gold layer 2 uinches thick is not likely to greatly
reduce cycles to failure. But if your pads are very small such as a
.004" flip chip pad with no solder paste added (reflowing the flipchip
solder only) and you put on a 5-8 uinch gold layer over nickel, then you
are approaching or exceeding the 1% limit. Having to form the IMC with
nickel doesn't help.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Guy Ramsey
Sent: Friday, December 29, 2006 1:33 PM
To: [log in to unmask]
Subject: Re: [TN] Questions on ENIG VS gold plating

Two would be fine if you could control the thickness across the board.
I am not aware of any either. But, electroplated gold is another story.


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lee parker
Sent: Friday, December 29, 2006 1:55 PM
To: [log in to unmask]
Subject: Re: [TN] Questions on ENIG VS gold plating

Guy

If two micro inches of gold is an embrittlement threat, then ENIG must
be considered equally as dangerous. I am hardly a fan of ENIG, but I am
unaware of any documented ENIG embrittlement failures.

Best regards

Lee

J. Lee Parker, Ph.D.
JLP Consultants LLC
804 779 3389


----- Original Message -----
From: "Guy Ramsey" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, December 29, 2006 1:09 PM
Subject: Re: [TN] Questions on ENIG VS gold plating


> I didn't read your paper but my experience mirrors Werner's. It is 
> very difficult to get a thin, even, always present electroplate. A two

> micro inch minimum might easily result in spots that are thick enough 
> to cause brittle solder connections. A two micro inch maximum might 
> easily fail to protect the nickel.
>
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Lee parker
> Sent: Friday, December 29, 2006 12:56 PM
> To: [log in to unmask]
> Subject: Re: [TN] Questions on ENIG VS gold plating
>
> Werner
>
> This could not be flash gold since in this process the gold thickness
is
> approximately 2 micro inches, which of course is where the name 
> originated.
> The advantage over ENIG is that the porosity is greatly reduced.
>
> I am sure you will agree two micro inches of gold is not going to
cause
> embrittlement. I imagine what you have is typical plated gold with
uses a
> completely different and much more expensive chemistry.
>
> Best regards
>
> Lee
>
> J. Lee Parker, Ph.D.
> JLP Consultants LLC
> 804 779 3389
>
>
> ----- Original Message -----
> From: "Werner Engelmaier" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Friday, December 29, 2006 12:47 PM
> Subject: Re: [TN] Questions on ENIG VS gold plating
>
>
> > In a message dated 12/29/06 11:25:43, [log in to unmask] writes:
> > > Many Asian shops use what they call "flash gold"
> > > which is electro plated gold over nickel.
> > >
> > Hi Lee,
> > True enough, but 2 of my clients in China had gold-embrittlement 
> > failures
> > because some of their product had too much Au on it.
> >
> > Werner
> >
> > ---------------------------------------------------
> > Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> > To unsubscribe, send a message to [log in to unmask] with following
text 
> > in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt or (re-start) delivery of Technet send e-mail to
> > [log in to unmask]: SET Technet NOMAIL or (MAIL)
> > To receive ONE mailing per day of all the posts: send e-mail to
> > [log in to unmask]: SET Technet Digest
> > Search the archives of previous posts at: 
> > http://listserv.ipc.org/archives
> > Please visit IPC web site 
> > http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>
> > for additional information, or contact Keach Sasamori at
[log in to unmask] 
> > or
>
> > 847-615-7100 ext.2815
> > -----------------------------------------------------
> >
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text
in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
http://listserv.ipc.org/archives
> Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at
[log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text
in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
http://listserv.ipc.org/archives
> Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16

> for additional information, or contact Keach Sasamori at
[log in to unmask] or

> 847-615-7100 ext.2815
> -----------------------------------------------------
> 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2