TECHNET Archives

January 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Steve Gregory <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Steve Gregory <[log in to unmask]>
Date:
Thu, 11 Jan 2007 07:22:50 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (71 lines)
Mornin' Bob,

Below is a pretty interesting paper that was done by Dr. Colin Drury
called; "Visual Inspection Reliability: What we know and why we need to
Know it."

http://www.hf.faa.gov/docs/508/docs/drury_doc.pdf

Although this paper is geared towards aircraft airworthiness inspection,
I think it's pertinent because the factors involved in visual inspection
is pretty much the same no matter what one is inspecting.

-Steve Gregory-

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of bob wettermann
Sent: Thursday, January 11, 2007 5:35 AM
To: [log in to unmask]
Subject: [TN] Manual Visual Inspection of PCB Assemblies

Ladies and Gents:

Perhaps you can shed some light on an issue I am sure many of you have
faced in the prototyping arena. This issue has to do with the
expectations one should have wrto to "catching" defects (missing, out or
rotation, solder joint problems, etc) for ultra low volume (10 or less
finished assemblies) or prototype PCB assemblies.

We have internalized that only 80 % (on a good day) of the board is
actually inspected  by even the best of QC inspectors. That  leaves 20%
of the board uninspected and one should come to expect, in the absence
of paying/having time  for in-circuit or functional testing, defects to
occur. This is just one of the downsides for building low  volume
(usually fast turn) PCB assemblies. Do you agree?

 Does anyone know of any round-robin testing in our industry that has
helped quantify or document the effectiveness of manual inspection? Has
a specific testing task force ever investigated this issue? Is there a
general industry need for such?

Regards

Bob Wettermann


Bob Wettermann
PH 847-767-5745

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)