Subject: | |
From: | |
Reply To: | |
Date: | Thu, 18 Jan 2007 15:12:00 +0200 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
To the best of my knowledge, the only common VOC-free soldering flux
consists of an aqueous solution of zinc or ammonium chloride in an
excess of hydrochloric acid. Try that on your electronics assemblies!!!
Even pure water-white rosin emits VOCs at soldering temperature.
Brian
Douglas McCall wrote:
> Hi to all,
> Can someone point me in the direction of any legislation that
> relates to the use of flux and future requirements to use VOC
> free flux.
>
> With respect to RoHS or any other specific legislation (such as
> 1999/13/EC),
> will it likely become a requirement (at sometime in the future) to use
> a VOC free flux and will they ban IPA solvent based fluxes.??
>
> Any info will be much appreciated.
>
> Thanks,
> Douglas I McCall
>
> Regards,
> Douglas I McCall,
> TRW Automotive,
> Mill Hill,
> North West Industrial Estate,
> Peterlee, SR8 2HR
> Tel: +44 (0)191 518 8918
> mailto: [log in to unmask]
> web-site: http://www.trwauto.com
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|