By the way, HiRel is in a way another word for Quality, they are cousins.
HiRel intentions can't be realized without a Quality Managing Program. I'll
give an example. You may all have such a one plan as good as the one I'll
show below, but we had not (I don't speak about  the whole company, but
about the microelectronics group, where I work at the moment). When I
presented the plan  for one of our bosses, he stood up and said 'Amen!'  We
will not copy MSK's program, but we will have that paper under our eyes when
we make our new Q plan, that's for sure.

http://www.mskennedy.com/client_images/catalog19680/pages/files/MS50QCMrj.pdf

Thanks a lot, MSK.

Inge
SMW



----- Original Message -----
From: "Pradeep" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, December 15, 2006 2:37 PM
Subject: [TN] Reliability Specs


Dear all,

We are a PCB manufacturer of multilayer PCB's catering to the high
reliability space segment. We are in the process of relooking at our
specifications to meet the customer requirements.

Couple of suggestions recvd are

1.    Thermal stress - 6 times at 290 deg C ( we are currently doing 1 cycle
at 288 deg C )

2.    Rework Simulation - 5 cycles at 300 deg C ( we are currently doing 5
cycles at 260 deg C)


Can the technet members provide some feedback on these suggestions which
will help us in deciding on the right specification

Rgds

Pradeep

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2