Bill,

Thanks, but, sorry, I am under a mutual NDA and cannot comment on
specific materials, whether or not I have tested them and what, if any,
the results were.

Bev

 

________________________________

From: Bill Kasprzak [mailto:[log in to unmask]] 
Sent: December 14, 2006 2:01 PM
To: TechNet E-Mail Forum; Bev Christian
Subject: Re: [TN] Qualifying reworkable underfills

 


Bev, 

Have you tried Loctite 3549? It caught my eye in a trade publication due
to it being re-workable. 

 



Bev Christian <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]> 

12/14/2006 01:50 PM 

Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
Bev Christian <[log in to unmask]>

To

[log in to unmask] 

cc

 

Subject

[TN] Qualifying reworkable underfills

 

 

 




Technetters,
Back after almost a year off-line.

It has always been my philosophy to thoroughly test ANY chemical that is
going to come in contact with a PCB or PCBA - tapes, labels, inks,
markers, adhesives, cleaners, temp solder masks, permanent solder masks,
flux stops, lubricants for compression fit pins, solder wicks, dusters,
freezing agents, OSPs, cored wires, fluxes, thinners, tacky fluxes,
paste fluxes, solder pastes, underfills, conformal coatings and thermal
compounds.

Lab testing includes copper mirror, halide ion, SIR and electrochemical
migration.  It sometimes includes other tests, but let's leave it at
this for the moment.

Here's my problem: I have tested many reworkable underfills from all the
people you can think of and I CAN'T FIND A SINGLE ONE THAT WILL PASS
BOTH IPC SIR AND ECM TESTING.  These materials were tested at the same
time that we had control coupons in the chamber (passed), solder pastes
(passed) and normal underfills (passed), so I doubt it was the chambers
(more than one) or that there were water droplets (checked, none
evident). 

My customers are pushing me to allow them to use the stuff and I am
resisting.  Comments, please.

Bev Christian
RIM



---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential
information, privileged material (including material protected by the
solicitor-client or other applicable privileges), or constitute
non-public information. Any use of this information by anyone other than
the intended recipient is prohibited. If you have received this
transmission in error, please immediately reply to the sender and delete
this information from your system. Use, dissemination, distribution, or
reproduction of this transmission by unintended recipients is not
authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------






---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2