TECHNET Archives

November 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Kevin Glidden <[log in to unmask]>
Reply To:
Date:
Thu, 30 Nov 2006 13:23:24 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (57 lines)
My take on this is that you are required to clean following ALL soldering
steps.  That is what the first "2" means - cleaning of both sides required.
You do wash the PCB after the water sol solder process, but the same
designator would apply to the secondary no-clean process, even if they do
pass the ionic cleanliness test (as required by the second "2" in C22).  Is
it really no clean, or RMA?

Kevin Glidden
Manufacturing Engineer
Astronics Luminescent Systems Inc.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Joel Alexander
Sent: Thursday, November 30, 2006 11:47 AM
To: [log in to unmask]
Subject: [TN] Question about J-STD-001 cleanliness designator C-22

We are processing some assemblies with water soluble flux that requires
washing.   We then wash the assemblies as required by C-22.  The next step
we add a some hand soldered parts with no clean VOC flux but do not clean
the assembly. We sample test the boards for ionic contamination and they
pass.

Should these be considered compliant since they pass or would the no-clean
solder have to also be washed of.

FYI this is for some military work.

Any help would be appreciated

Joel Alexander

APSCO Quality Assurance Manager

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------