Roger Mack <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Roger Mack <[log in to unmask]>
Date:
Mon, 27 Nov 2006 14:24:38 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (144 lines)
It looks like a mark from a metal probe or tweezer. When we send parts out for analysis we try hard to find examples that have not been touched during testing otherwise the conversation about route cause alway points to these marks. 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Stadem, Richard D.
Sent: Monday, November 27, 2006 13:26
To: [log in to unmask]
Subject: Re: [TN] Soldering Anomaly


Can't tell a lot from a single picture, but that little spur on the side
of the solder joint makes me think someone is doing solder touchup
without benefit of flux. 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of stephengregory5849
Sent: Monday, November 27, 2006 11:23 AM
To: [log in to unmask]
Subject: Re: [TN] Soldering Anomaly

Hi Everyone!

Well, I finally got Pat's picture up! The reason it's taken me so long
is because I'm back home in North Carolina, and the only internet access
I have is dial-up at a screaming 26.4 KB per second! I remember not that
long ago that was fast. But once you get used to a DSL or T1 connection,
well that's just dog slow.

Anyways, here's Pat's picture:

http://www.stevezeva.homestead.com/files/solder_anomaly2.JPG

To me that doesn't look right. I've soldered with a Sn62/Pb36/Ag2 paste
before and soldered lead-free components on a ENIG board and the joints
didn't look that rough. That's more than just cooling lines IMHO...

-Steve Gregory-

----- Original Message -----
From: "Diamond, Pat" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Monday, November 27, 2006 2:12 AM
Subject: [TN] Soldering Anomaly


> Hi Technetters,
>
> We have recently received some assembled boards from a new supplier 
> and upon carrying out a First Article Inspection on them I noticed 
> what I thought were disturbed solder joints.  I then referred to 
> IPC-610 which seemed to confirm this.  Upon talking to the supplier 
> about this problem they said that this was not disturbance but 
> "cooling lines" due to the fact that the component leads were 
> lead-free and the solder paste was Sn62/Pb36/Ag2.
> They referred me to IPC-610 Para. 5.2.7 Fig. 5.56 (page 5-18) which 
> looks nothing like the joints on our components.  The only area this 
> anomaly is occurring is on the SOT 23 Transistors & Diodes.
> Our company is not a main line SMT producer and I have never seen this

> anomaly before.
>
> I have contacted Steve Gregory and he has kindly agreed to post a 
> couple of pictures on his website for me, see what you think.
>
> I really hope they are cooling lines!!!
>
> Thanks in advance for any help/advice you can offer.
>
> Best regards,
>
> Pat
>
>
> **********************************************************************
> ******
> ***************
> The information transmitted is intended only for the person or entity 
> to which it is addressed and may contain confidential and/or 
> privileged material.
>
> Any review, retransmission, dissemination or other use of, or taking 
> of any action in reliance upon, this information by persons or 
> entities other than the intended recipient is prohibited. If you 
> received this in error, please contact the sender and delete the 
> material from any computer.
> **********************************************************************
> ******
> ***************
> Mr Pat Diamond
> Senior Specialist Engineer
> Weston Aerospace                Tel:     +44 (0)1252  868122
> 124 Victoria Road               Fax:    +44 (0)1252 370298
> Farnborough, Hampshire, GU14 7PW        Web    www.westonaero.com>
> England         Email  mailto:[log in to unmask]
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To 
> unsubscribe, send a message to [log in to unmask] with following text in

> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt 
> or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing 
> per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: 
> http://listserv.ipc.org/archives Please visit IPC web site 
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at 
> [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2