Many thanks all for your responses, the team have come good again! 

I guess I wasn't far off the mark then, looks like some discussions with the Design Team are order of the day!

Regards,
        Iain.

-----Original Message-----
From: Wenger, George M. [mailto:[log in to unmask]]
Sent: 24 November 2006 15:49
To: TechNet E-Mail Forum; Braddock, Iain
Subject: RE: [TN] FW: [TN] BGA anomaly


Iain,

You've stated correctly the dilemma companies are facing.  You've
comment/question about option 2 creating a reliability concern and also
invalidating the manufacturers warranty is also correct.  Companies are
going to have to make their own risk assessments.  Unfortunately, many
of those decisions are not knowledge based decisions because there isn't
good documented information available. The recommendations I've made
internally are:

1. Use SnPb assembly whenever possible
2. Use Pb-Free components and processes when product needs to be RoHS
6/6 compliant.
3. When forced into mixed alloy assembly:
        a. For RoHS 6/6 product, use Pb-Free processes (245-260C) when
all             components are compatible with Pb-Free processes.
        b). For RoHS 5/6 product, use maximum SnPb process temperatures
(225-           235C) whenever there are components not compatible with
Pb-Free                 processes (i.e., don't exceed the maximum
temperature the MSL             was tested at by the component vendor.
        c). Do not re-ball Pb-Free area array packages with SnPb balls.

Regards,
George
George M. Wenger
Andrew Corporation Wireless Network Solutions
Senior Principal FMA / Reliability Engineer
40 Technology Drive, Warren, NJ 07059
(908) 546-4531 [Office]  (732) 309-8964 [Cell]
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Braddock, Iain
Sent: Friday, November 24, 2006 7:43 AM
To: [log in to unmask]
Subject: Re: [TN] FW: [TN] BGA anomaly

This sure is an interesting dilemma!

So which is the lesser of the two evils assuming you are forced into it
with the Design?

        1)      SnPb / SAC BGA's with a temperature profile (230ish)
that allows all joints to go liquidus.
        2)      Reball SAC BGA's with SnPb balls & use standard SnPb
thermal profile.

If option 2 does that not create reliability concerns also invalidate
the manufacturers warranty?

Regards,
        Iain.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Werner Engelmaier
Sent: 22 November 2006 17:39
To: [log in to unmask]
Subject: Re: [TN] FW: [TN] BGA anomaly


               *** WARNING ***

This mail has originated outside your organization,
either from an external partner or the Global Internet. 
     Keep this in mind if you answer this message. 

Hi Ramon,
Mixing SnPb with SAC is not a very good idea--you are right.



Werner

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------


********************************************************************
This email and any attachments are confidential to the intended
recipient and may also be privileged. If you are not the intended
recipient please delete it from your system and notify the sender.
You should not copy it or use it for any purpose nor disclose or
distribute its contents to any other person.
********************************************************************

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------


------------------------------------------------------------------------------------------------
This message is for the designated recipient only and may
contain privileged, proprietary, or otherwise private information.  
If you have received it in error, please notify the sender
immediately and delete the original.  Any unauthorized use of
this email is prohibited.
------------------------------------------------------------------------------------------------
[mf2]


********************************************************************
This email and any attachments are confidential to the intended
recipient and may also be privileged. If you are not the intended
recipient please delete it from your system and notify the sender.
You should not copy it or use it for any purpose nor disclose or
distribute its contents to any other person.
********************************************************************

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2