Hi Bogert

Happy turkey day!

I have to ask, do you apply conformal coating?  If so, how do you apply
it under things like pin grid array parts?  Quad flatpacks?  Vertical
plug connectors where you don't have access to the top side solder
joints?  DC/DC converter blocks?  SMT Chip resistors?

Sorry, but I've got to disagree with you.  I've never seen a drawing
that specified "no coating required" under shadowed parts, and I have
never talked with a quality engineer or process engineer who thought
that meant coating under the parts (maybe you are the first, what is
your job???).


regards,

Graham Collins
Process Engineer,
L-3 Communications Electronic Systems Inc.
Halifax
(902) 873-2000 ext 6215

>>> [log in to unmask] 11/23/06 03:27PM >>>
November 23, 2006

Dave, happy turkey day.  My response did not mean I agree that
conformal coating should in fact be applied under a component.  What I
indicated was that if the drawing specifically mandated that the
assembly be conformal coated, then the expectation is that coating must
be applied under, over, and everywhere else on the assembly unless the
assembly drawing specifically requires masking free of certain areas
from conformal coating..  If conformal coating should not be applied
under a part, then the drawing needs to say so.
  ----- Original Message -----
  From: David D. Hillman<mailto:[log in to unmask]>
  To: [log in to unmask]<mailto:[log in to unmask]>
  Sent: Monday, November 20, 2006 6:27 PM
  Subject: Re: [TN] BGA and conformal coating


  Hi Bogert! Sorry but I respectfully disagree. If the contract
requires the
  assembly to be conformal coating and provides no other process
guidance
  then I would process the assembly in accordance with best industry
  practice/accepted material process practice for the particular
conformal
  coating material specified. As other TechNettees have documented,
  intentionally forcing AR or UR conformal coating under a component is
not
  standard conformal coating practice as the such an action results in
  degraded component/product integrity due to CTE mismatch for many
use
  environments. However, if I was using a paralyene conformal coating,
  standard material process practice is quite the opposite - paralyene
  conformal coating is design to coat all pwa surfaces. The
application
  process for each conformal coating material dictates how/where it
should be
  applied unless there are specific instruction that deviate from
standard
  practice (such as a specific exclusion area for RF, etc.).

  Dave



               - Bogert
               <[log in to unmask]<mailto:[log in to unmask]>>
               Sent by: TechNet
  To
               <[log in to unmask]<mailto:[log in to unmask]>>
[log in to unmask]<mailto:[log in to unmask]>

  cc

               11/20/2006 03:52
Subject
               PM                        Re: [TN] BGA and conformal
coating


               Please respond to
                TechNet E-Mail
                     Forum
               <[log in to unmask]<mailto:[log in to unmask]>>
               ; Please respond
                      to
                   - Bogert
               <[log in to unmask]<mailto:[log in to unmask]>>






  If the contract assembly drawing requires the assembly to be
conformal
  coated, unless it also allows the area under the BGA to be free of
coating,
  then you are in violation of the contract drawing regardless of what
610
  says or does not say.
    ----- Original Message -----
    From: David D.
Hillman<mailto:[log in to unmask]<mailto:[log in to unmask]>>
    To:
[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>
    Sent: Monday, November 20, 2006 2:20 PM
    Subject: Re: [TN] BGA and conformal coating


    Hi Joe - Your statement......." type AR or type UR does not coat
the BGA
    solder balls/solder connections located under the BGA so you are
  violating
    the acceptability requirements in IPC-A-610" has me some confused.
What
    IPC-A-610 requirement is violated?

    Dave Hillman
    Rockwell Collins

[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>




                 "Macko, Joe @
                 IEC"

<joe.macko@L-3COM<mailto:joe.macko@L-3COM<mailto:joe.macko@L-3COM<mailto:joe.macko@L-3COM>>
  To
                 .COM>
[log in to unmask]<mailto:[log in to unmask]><
  mailto:[log in to unmask]<mailto:[log in to unmask]>>
                 Sent by: TechNet
  cc

<[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>>

  Subject
                                           Re: [TN] BGA and conformal
coating
                 11/20/2006 12:47
                 PM


                 Please respond to
                  TechNet E-Mail
                       Forum

<[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>>
                 ; Please respond
                        to
                   "Macko, Joe @
                       IEC"

<joe.macko@L-3COM<mailto:joe.macko@L-3COM<mailto:joe.macko@L-3COM<mailto:joe.macko@L-3COM>>
                       .COM>






    Vered,

    I would start with IPC-A-610 and J-STD-001 documents. One item that
is
  over
    looked is that spraying a board with for example type AR or type UR
does
    not
    coat the BGA solder balls/solder connections located under the BGA
so you
    are violating the acceptability requirements in IPC-A-610!

    Good luck,
    - Joe


    -----Original Message-----
    From: Vered BS [mailto:[log in to unmask]]
    Sent: Monday, November 20, 2006 8:40 AM
    To:
[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>
    Subject: [TN] BGA and conformal coating

    looking for reviews/articles or case studies regarding conformal
coating
  on
    BGA
    for military/aerospace environment
    Appreciate any comment or sharing your experiance
    Thanks
    Vered

    ---------------------------------------------------
    Technet Mail List provided as a service by IPC using LISTSERV 1.8e
    To unsubscribe, send a message to
[log in to unmask]<mailto:[log in to unmask]><
  mailto:[log in to unmask]<mailto:[log in to unmask]>> with following text
in
    the BODY (NOT the subject field): SIGNOFF Technet
    To temporarily halt or (re-start) delivery of Technet send e-mail
to

[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>:
SET Technet NOMAIL or (MAIL)
    To receive ONE mailing per day of all the posts: send e-mail to

[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>:
SET Technet Digest
    Search the archives of previous posts at:

http://listserv.ipc.org/archives<http://listserv.ipc.org/archives<http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>>
    Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16><

http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16>>
    for additional information, or contact Keach Sasamori at
[log in to unmask]<mailto:[log in to unmask]><
  mailto:[log in to unmask]<mailto:[log in to unmask]>> or
    847-615-7100 ext.2815
    -----------------------------------------------------

    ---------------------------------------------------
    Technet Mail List provided as a service by IPC using LISTSERV 1.8e
    To unsubscribe, send a message to
[log in to unmask]<mailto:[log in to unmask]><
  mailto:[log in to unmask]<mailto:[log in to unmask]>> with following text
in
    the BODY (NOT the subject field): SIGNOFF Technet
    To temporarily halt or (re-start) delivery of Technet send e-mail
to

[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>:
SET Technet NOMAIL or (MAIL)
    To receive ONE mailing per day of all the posts: send e-mail to

[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>:
SET Technet Digest
    Search the archives of previous posts at:

http://listserv.ipc.org/archives<http://listserv.ipc.org/archives<http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>>
    Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16><

http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16>>
    for additional information, or contact Keach Sasamori at
[log in to unmask]<mailto:[log in to unmask]><
  mailto:[log in to unmask]<mailto:[log in to unmask]>> or
    847-615-7100 ext.2815
    -----------------------------------------------------

    ---------------------------------------------------
    Technet Mail List provided as a service by IPC using LISTSERV 1.8e
    To unsubscribe, send a message to
[log in to unmask]<mailto:[log in to unmask]><
  mailto:[log in to unmask]<mailto:[log in to unmask]>> with following text
in
    the BODY (NOT the subject field): SIGNOFF Technet
    To temporarily halt or (re-start) delivery of Technet send e-mail
to

[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>:
SET Technet NOMAIL or (MAIL)
    To receive ONE mailing per day of all the posts: send e-mail to

[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]<mailto:[log in to unmask]>>:
SET Technet Digest
    Search the archives of previous posts at:

http://listserv.ipc.org/archives<http://listserv.ipc.org/archives<http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>>
    Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16><

http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16>>
for additional
  information, or contact Keach Sasamori at
[log in to unmask]<mailto:[log in to unmask]><
  mailto:[log in to unmask]<mailto:[log in to unmask]>> or 847-615-7100
ext.2815
    -----------------------------------------------------

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to
[log in to unmask]<mailto:[log in to unmask]> with following text
in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to
  [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or
(MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to
  [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at:
http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16>
  for additional information, or contact Keach Sasamori at
[log in to unmask]<mailto:[log in to unmask]> or
  847-615-7100 ext.2815
  -----------------------------------------------------

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to
[log in to unmask]<mailto:[log in to unmask]> with following text
in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or
(MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at:
http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16>
for additional information, or contact Keach Sasamori at
[log in to unmask]<mailto:[log in to unmask]> or 847-615-7100 ext.2815
  -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2