Hi Ramon

Any coating at 33% solids or more is unlikely to penetrate fully  
beneath a BGA even when dip coating - with the exception of silicones  
as they have really low surface energy.

To rely on "natural product shrinkage" to avoid any fillets would be  
a little risky and how could you know for sure?

Kindest regards,

Graham Naisbitt

[log in to unmask]



On 22 Nov 2006, at 14:21, Dehoyos, Ramon wrote:

>         Hi Graham:
>                     I have not made detailed experiments as you and  
> Brian have. CC at 33% solids and 66% solvents when squirted under  
> the BGA will adhere to all surfaces when wet. When it dries it  
> shrinks significantly leaving plenty room for expansion. My  
> question: Wouldn't it work based on the fact that the CC is shrunk?
>         Best Regards,
>         Ramon
>
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Graham Naisbitt
> Sent: Tuesday, November 21, 2006 12:32 PM
> To: [log in to unmask]
> Subject: Re: [TN] BGA and conformal coating
>
> Vered
>
> This is an old and thorny subject much debated on the TechNet in  
> the past.
>
> The TCE of apretty much all conformal coatings is >300ppm/DegC but  
> the TCE of silicones are huge at ~300-350ppm/°C Solder being only  
> ~16 ppm/°C this is a pretty significant TCE mismatch.
>
> As for silicones as debated by Brian Ellis and myself some time  
> ago, Brian said: They have a unique property that however soft they  
> feel, they are rock-hard when subjected to mechanical shock (hence  
> super- bouncing balls and bouncing putty) At only slightly elevated  
> temperatures there would be tension on a BGA-ball-pad combination,  
> that would increase by orders of magnitude should it be subjected  
> to a small shock at the same time
>
> If you must under-fill, then a soft purpose developed epoxy is the  
> probable answer, check with Brian Toleno - wherever he is hiding  
> these days?
>
> Having said all of that, I have had aerospace customers who apply a  
> very thin coating, diluting the coating and dipping at very slow  
> speeds, that can ensure (as far as one can without removing the  
> device to check!) coverage under the device. They then apply a  
> "conventional" spray coat to complete the job.
>
> I hope this helps
>
> Regards,
>
> Graham Naisbitt
>
> Gen3 Systems - Engineering Reliability in Electronics
>
> [log in to unmask]
>
>
>
> On 20 Nov 2006, at 16:40, Vered BS wrote:
>
>> looking for reviews/articles or case studies regarding conformal
>> coating on BGA for military/aerospace environment Appreciate any
>> comment or sharing your experiance Thanks Vered
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
>> unsubscribe, send a message to [log in to unmask] with following  
>> text in
>> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt
>> or (re-start) delivery of Technet send e-mail to [log in to unmask]:  
>> SET
>> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
>> posts: send e-mail to
>> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at: http://listserv.ipc.org/
>> archives Please visit IPC web site http://www.ipc.org/ 
>> contentpage.asp?
>> Pageid=4.3.16 for additional information, or contact Keach  
>> Sasamori at
>> [log in to unmask] or 847-615-7100 ext.2815
>> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e  
> To unsubscribe, send a message to [log in to unmask] with following  
> text in the BODY (NOT the subject field): SIGNOFF Technet To  
> temporarily halt or (re-start) delivery of Technet send e-mail to  
> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE  
> mailing per day of all the posts: send e-mail to [log in to unmask]:  
> SET Technet Digest Search the archives of previous posts at: http:// 
> listserv.ipc.org/archives Please visit IPC web site http:// 
> www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional  
> information, or contact Keach Sasamori at [log in to unmask] or  
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following  
> text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail  
> to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to  
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/ 
> archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp? 
> Pageid=4.3.16 for additional information, or contact Keach Sasamori  
> at [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2