TECHNET Archives

November 2006

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
- Bogert <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, - Bogert <[log in to unmask]>
Date:
Mon, 20 Nov 2006 16:52:17 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (121 lines)
If the contract assembly drawing requires the assembly to be conformal coated, unless it also allows the area under the BGA to be free of coating, then you are in violation of the contract drawing regardless of what 610 says or does not say.
  ----- Original Message ----- 
  From: David D. Hillman<mailto:[log in to unmask]> 
  To: [log in to unmask]<mailto:[log in to unmask]> 
  Sent: Monday, November 20, 2006 2:20 PM
  Subject: Re: [TN] BGA and conformal coating


  Hi Joe - Your statement......." type AR or type UR does not coat the BGA
  solder balls/solder connections located under the BGA so you are violating
  the acceptability requirements in IPC-A-610" has me some confused. What
  IPC-A-610 requirement is violated?

  Dave Hillman
  Rockwell Collins
  [log in to unmask]<mailto:[log in to unmask]>




               "Macko, Joe @
               IEC"
               <joe.macko@L-3COM<mailto:joe.macko@L-3COM>                                          To
               .COM>                     [log in to unmask]<mailto:[log in to unmask]>
               Sent by: TechNet                                           cc
               <[log in to unmask]<mailto:[log in to unmask]>>
                                                                     Subject
                                         Re: [TN] BGA and conformal coating
               11/20/2006 12:47
               PM


               Please respond to
                TechNet E-Mail
                     Forum
               <[log in to unmask]<mailto:[log in to unmask]>>
               ; Please respond
                      to
                 "Macko, Joe @
                     IEC"
               <joe.macko@L-3COM<mailto:joe.macko@L-3COM>
                     .COM>






  Vered,

  I would start with IPC-A-610 and J-STD-001 documents. One item that is over
  looked is that spraying a board with for example type AR or type UR does
  not
  coat the BGA solder balls/solder connections located under the BGA so you
  are violating the acceptability requirements in IPC-A-610!

  Good luck,
  - Joe


  -----Original Message-----
  From: Vered BS [mailto:[log in to unmask]]
  Sent: Monday, November 20, 2006 8:40 AM
  To: [log in to unmask]<mailto:[log in to unmask]>
  Subject: [TN] BGA and conformal coating

  looking for reviews/articles or case studies regarding conformal coating on
  BGA
  for military/aerospace environment
  Appreciate any comment or sharing your experiance
  Thanks
  Vered

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to
  [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to
  [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16>
  for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or
  847-615-7100 ext.2815
  -----------------------------------------------------

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to
  [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to
  [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16>
  for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or
  847-615-7100 ext.2815
  -----------------------------------------------------

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to [log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at: http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentpage.asp?Pageid=4.3.16> for additional information, or contact Keach Sasamori at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100 ext.2815
  -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2