Hi Iain,
Perhaps you have not seen some of my previous responses, but...
For reflow soldering, the time-above-Solidus is not an important number for
solder joint quality; you are not making solder joints at or just above
Solidus. However, time-above-(Liquidus+20C [if soldering to Ni you need
Liquidus+30C]) is very important and should be 3 to 5 seconds or longer.
Unfortunately, paste vendors have been misleading their customers for a long
time with this "time-above-183" nonsense, that is now spilling over into the
LF-arena.

Werner

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2