Further to Thad's question, does the IPC spec refer to the spacing
between SMT pads of adjacent components or does it refer to the spacing
between the component bodies themselves? Some comps extend beyond the
SMT pads while others do not.

Craig Cullum, Engineering Technologist, AMTELCO
e: [log in to unmask]
   [log in to unmask]
f: 608 838 8367
v: 608 838 4194, or 4197, x128

Please visit us at www.amtelco.com 

> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Thad Schultz
> Sent: Tuesday, October 31, 2006 11:21 AM
> To: [log in to unmask]
> Subject: [TN] Recommended SMD to SMD clearances?
> 
> All,
> 
> What IPC spec discusses recommended SMD to SMD clearances?  
> We are trying to update our internal documents to coincide 
> with the latest industry standards.  What I am after is the 
> recommended SMD to SMD clearances when laying out a PCB.  
> What should discrete chip to discrete chip spacings be?  SOIC 
> to SOIC?  Discrete to SOIC?  PLCC to PLCC?  Basically all 
> combinations of one part type to another including the 
> different possible rotations.  I have an old diagram from 
> IPC-SM-782 but I think it is outdated and replaced by another 
> IPC spec.  Any help would be appreciated.
> 
> Thanks.
> 
> Thad Schultz
> EDA Librarian / Sys Admin
> Woodward Industrial Controls
> [log in to unmask]
> ph (970)498-3570
> fax (970)498-3077
> www.woodward.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2