I have had failures associated with overtorquing a screw to the point
that it pressed through the laminate and shorted to an internal trace.
Pretty severe overtorge (basically they didn't use a torque limited
device at all); I would point out however that this type of mechanical
damage should be rejectable to 610 (irregardless of the root cause.)
Jim
=================================
Jim Maguire
Intel Corporation
Engineering Support -
Dupont Corporate Environmental Lab
Ph 253-371-4065
Fx 253-371-5779
pager 866-217-5222 [log in to unmask]
Email [log in to unmask]
=================================
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Jack Olson
Sent: Thursday, October 12, 2006 11:54 AM
To: [log in to unmask]
Subject: [TN] Compression Limit on FR4?
Does anyone know of any guidelines or recommendations that
suggest a maximum limit on compressing board material?
Can any damage occur by over-torque'n screws, for example?
I've never heard anyone discuss that...
Jack
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|