Joe,

In the MIL-PRF-55110 document (currently at rev G1) there is the statement
"Inactive for new design after 31 December 1997. For new designs use
MIL-PRF-31032".

The MIL-PRF-55110 document is not cancelled per se' as many drawings still
require product to be fabricated to the specification.

If the drawing states MIL-P[RF]-55110 it must be fabricated to the
specification unless the customer allows you to apply a different acceptance
document (i.e. IPC 6012) but then they would have had to received approval
from the end user or even DSCC (Defense Supply Center, Columbus).

The process I'm sure, to gain approval to use the IPC standard would be
arduous.

Regarding revision levels of MIL-PRF-55110. Even though a specific revision
level is identified on the drawing, in this instance revision C, a
fabricator can apply the latest revision provided all requirements of
revision C are met. If you look at appendix D in the 55110 document it
explains this, in my conversations with DSCC VQE personnel their comments
lead me to believe they would prefer this (actually they prefer one
transition to MIL-PRF-31032A).

There are many people that will tell you if it states revision C for
example, then one would have to apply criteria in revision C and certify it
to that. If this were true I respond with why would DSCC then continue to
make revisions to the 55110 document after 1997, as the document can only be
used for existing projects.

The revisions to MIL-PRF-55110 change just like every other standard, due to
new information, data, methods, equipment, fabricator capabilities, etc, and
the 55110 document while not the preferred document by DSCC, must change
with the times.

I hope this helps.

Regards,

Franklin D Asbell


  ----- Original Message -----
  From: Kane, Joseph E (US SSA)<mailto:[log in to unmask]>
  To: [log in to unmask]<mailto:[log in to unmask]>
  Sent: Thursday, July 27, 2006 9:12 AM
  Subject: [TN] MIL-P-55110


  Our PWB expert is out on vacation, and I'm being drawn
  into a discussion with a customer about 55110C.

  We've moved to 6011/6012 for rigid boards, but I'm not sure
  exactly how we've documented or justified this change.

  My understanding is that the Mil spec has changed
  into a PRF, currently at Rev. G, and it's a practical
  impossibility to comply with 55110C because DSCC has
  gotten out of the business of administering the requirements.

  It would be great if I could show the customer a cancellation
  notice for 55110 that points to the IPC specs, but I can't
  seem to find one.

  Can anyone illuminate the trail please?

  Joe Kane
  BAE Systems
  Johnson City NY

  ---------------------------------------------------
  Technet Mail List provided as a service by IPC using LISTSERV 1.8e
  To unsubscribe, send a message to
[log in to unmask]<mailto:[log in to unmask]> with following text in
  the BODY (NOT the subject field): SIGNOFF Technet
  To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]<mailto:[log in to unmask]>: SET Technet NOMAIL or (MAIL)
  To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]<mailto:[log in to unmask]>: SET Technet Digest
  Search the archives of previous posts at:
http://listserv.ipc.org/archives<http://listserv.ipc.org/archives>
  Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16<http://www.ipc.org/contentp
age.asp?Pageid=4.3.16> for additional information, or contact Keach Sasamori
at [log in to unmask]<mailto:[log in to unmask]> or 847-615-7100 ext.2815
  -----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2