Hi Lina
The current Thermal Shock test in the IPC-TM-650 has both electrical and
microsection evaluation.  The reason for this is the fact that electrical
measuring techniques may or may not be adequate to "catch" the cracking going on
within the barrel.  Samples must meet the requirements of both evaluations to be
considered compliant.  Since your electrical test setup is not catching the
cracking I would investigate the electrical wiring - the times at which
measurements are made etc.

The samples would not be compliant due to the barrel cracking found in the
microsections.

Susan Hott
President
Robisan Laboratory, Inc
6502 E 21st Street
Indianapolis, IN 46219

317-353-6249

www.robisan.com

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2